Medical Consumables by Specialty

BSI Multicare Cholesterol Medical Consumables by Specialty 25 pcs

  • Sample for use: fresh whole blood from capillary vessels or venous blood with K-EDTA or Li-Heparin as an anticoagulant.
  • Hematocrit range: 35-50%.
  • Measurement range: 130-400 mg/dl, (3.9-10.3 mmol/l).
  • ...
  • Sample for use: fresh whole blood from capillary vessels or venous blood with K-EDTA or Li-Heparin as an anticoagulant.
  • Hematocrit range: 35-50%.
  • Measurement range: 130-400 mg/dl, (3.9-10.3 mmol/l).
  • Sensitivity: minimum measurable result: 150 mg/dl.
  • Accuracy: Mean error of the Multicare system compared to the reference method is <10%. y = 1.0 x - 2.0 is the...
See full description See full description

Description

Description

  • Sample for use: fresh whole blood from capillary vessels or venous blood with K-EDTA or Li-Heparin as an anticoagulant.
  • Hematocrit range: 35-50%.
  • Measurement range: 130-400 mg/dl, (3.9-10.3 mmol/l).
  • Sensitivity: minimum measurable result: 150 mg/dl.
  • Accuracy: Mean error of the Multicare system compared to the reference method is <10%. y = 1.0 x - 2.0 is the linear relationship of measurements performed in a hospital.
  • Precision-repeatability: Mean inaccuracy <5%.
  • In a series of measurements performed in a laboratory, a mean coefficient of deviation of 2.48% was achieved.
  • Reproducibility: Mean inaccuracy is <5%.
  • In a series of measurements performed in a laboratory, a mean coefficient of deviation of 2.79% was achieved.
  • Average reading time: approximately 30’’.
  • Temperature range for strip use: 5-45°C.
  • Expiration date after opening: 90 days.
  • Storage temperature: 5°C-30°C,
  • Storage duration: 24 months.

Manufacturer

See full description

Specifications

Specifications

Medical Speciality
Other Specialties
Quantity
25 pcs

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

  • Sample for use: fresh whole blood from capillary vessels or venous blood with K-EDTA or Li-Heparin as an anticoagulant.
  • Hematocrit range: 35-50%.
  • Measurement range: 130-400 mg/dl, (3.9-10.3 mmol/l).
  • Sensitivity: minimum measurable result: 150 mg/dl.
  • Accuracy: Mean error of the Multicare system compared to the reference method is <10%. y = 1.0 x - 2.0 is the linear relationship of measurements performed in a hospital.
  • Precision-repeatability: Mean inaccuracy <5%.
  • In a series of measurements performed in a laboratory, a mean coefficient of deviation of 2.48% was achieved.
  • Reproducibility: Mean inaccuracy is <5%.
  • In a series of measurements performed in a laboratory, a mean coefficient of deviation of 2.79% was achieved.
  • Average reading time: approximately 30’’.
  • Temperature range for strip use: 5-45°C.
  • Expiration date after opening: 90 days.
  • Storage temperature: 5°C-30°C,
  • Storage duration: 24 months.

Manufacturer

Medical Speciality
Other Specialties
Quantity
25 pcs

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

53,00 €
14,00 €   shipping cost