Phase Relays

ETI ETI Phase Relays Earth Leakage 40A Bipolar

The 1P+N 40A 30mA type A RCCB residual current switch is an electrical protection device that disconnects the electrical circuit when an imbalance is detected between the incoming and outgoing...

The 1P+N 40A 30mA type A RCCB residual current switch is an electrical protection device that disconnects the electrical circuit when an imbalance is detected between the incoming and outgoing current, providing protection against electric shock.

  • Activation with indicator
  • Connection to busbars
  • Designed for later installation of additional devices
  • Protection...
See full description See full description

Description

Description

The 1P+N 40A 30mA type A RCCB residual current switch is an electrical protection device that disconnects the electrical circuit when an imbalance is detected between the incoming and outgoing current, providing protection against electric shock.

  • Activation with indicator
  • Connection to busbars
  • Designed for later installation of additional devices
  • Protection against frequent operational interruptions
  • High reliability in polluted environments
  • Circuit separation after disconnection
  • Can be used as an on/off switch for circuits and motors
  • Rated current: 40A
  • Rated voltage: 230/240 V
  • Mounting on DIN rail (TH/TS 35)
  • Maximum terminal capacity: 25 mm²
  • Startup time for internal installation
  • Dimensions: width 36mm, height 87mm, depth 69.7mm
  • Rated residual current: 30 mA
  • Protection level: IP 20
  • Rated short-circuit current: 10 kA
  • Impulse voltage resistance: 0.4 kA
  • Width in number of modules: 2
  • Startup indicator: yes
  • Connection possibility to side rails: yes
  • IEC/EN 61008 declarations
  • Number of poles: 2

Manufacturer

See full description

Specifications

Specifications

Type
Earth Leakage
Number of Poles
2
Nominal Voltage
40 A
Leakage Current
30 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type A

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

The 1P+N 40A 30mA type A RCCB residual current switch is an electrical protection device that disconnects the electrical circuit when an imbalance is detected between the incoming and outgoing current, providing protection against electric shock.

  • Activation with indicator
  • Connection to busbars
  • Designed for later installation of additional devices
  • Protection against frequent operational interruptions
  • High reliability in polluted environments
  • Circuit separation after disconnection
  • Can be used as an on/off switch for circuits and motors
  • Rated current: 40A
  • Rated voltage: 230/240 V
  • Mounting on DIN rail (TH/TS 35)
  • Maximum terminal capacity: 25 mm²
  • Startup time for internal installation
  • Dimensions: width 36mm, height 87mm, depth 69.7mm
  • Rated residual current: 30 mA
  • Protection level: IP 20
  • Rated short-circuit current: 10 kA
  • Impulse voltage resistance: 0.4 kA
  • Width in number of modules: 2
  • Startup indicator: yes
  • Connection possibility to side rails: yes
  • IEC/EN 61008 declarations
  • Number of poles: 2

Manufacturer

Type
Earth Leakage
Number of Poles
2
Nominal Voltage
40 A
Leakage Current
30 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type A

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

66,63 €