Phase Relays

Abb Phase Relay Earth Leakage 20A Bipolar

2P leakage switch with integrated miniature circuit breaker elements for protection against overloads, short circuits, and earth leakage. Ideal for use in residential and commercial applications.

  • ...

2P leakage switch with integrated miniature circuit breaker elements for protection against overloads, short circuits, and earth leakage. Ideal for use in residential and commercial applications.

  • Rated current (I n): 20A
  • Number of poles: 2
  • Surge category: III
  • Rated residual current: 30mA
  • Rated short-circuit capacity: 6 kA
  • Rated frequency: 50Hz
  • ...
See full description See full description

Description

Description

2P leakage switch with integrated miniature circuit breaker elements for protection against overloads, short circuits, and earth leakage. Ideal for use in residential and commercial applications.

  • Rated current (I n): 20A
  • Number of poles: 2
  • Surge category: III
  • Rated residual current: 30mA
  • Rated short-circuit capacity: 6 kA
  • Rated frequency: 50Hz
  • Characteristic disconnect: C
  • Type of leakage current: AC
  • Flexible cable cross-section: 1x 25 ... 25 mm²
  • Rigid cable cross-section: 1x 25 ... 25 mm²
  • Operating temperature: -25 ... 55 °C
  • Degree of protection: IP2X

Manufacturer

See full description

Specifications

Specifications

Type
Earth Leakage
Number of Poles
2
Nominal Voltage
20 A
Leakage Current
30 mA
with Energy Consumption Meter
No
with Timer
No

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

2P leakage switch with integrated miniature circuit breaker elements for protection against overloads, short circuits, and earth leakage. Ideal for use in residential and commercial applications.

  • Rated current (I n): 20A
  • Number of poles: 2
  • Surge category: III
  • Rated residual current: 30mA
  • Rated short-circuit capacity: 6 kA
  • Rated frequency: 50Hz
  • Characteristic disconnect: C
  • Type of leakage current: AC
  • Flexible cable cross-section: 1x 25 ... 25 mm²
  • Rigid cable cross-section: 1x 25 ... 25 mm²
  • Operating temperature: -25 ... 55 °C
  • Degree of protection: IP2X

Manufacturer

Type
Earth Leakage
Number of Poles
2
Nominal Voltage
20 A
Leakage Current
30 mA
with Energy Consumption Meter
No
with Timer
No

Important information