Voltage Monitors

Tele E1YM400VS10 Three-phase Voltage Monitor 03.031.0006

  • Measurement range: Un=400/230VAC.
  • Contacts (N)-L1-L2-L3.
  • Measurement functions: phase sequence & phase loss, undervoltage (UNDER), undervoltage & phase sequence control (UNDER+SEQ), min-max control...
  • Measurement range: Un=400/230VAC.
  • Contacts (N)-L1-L2-L3.
  • Measurement functions: phase sequence & phase loss, undervoltage (UNDER), undervoltage & phase sequence control (UNDER+SEQ), min-max control (WIN), min-max control & phase sequence (WIN+SEQ).
  • Settings: delay – max – min – function.
  • Tripping delay: 0.1s – 10s.
  • Cut-off limit: Maximum 80% to 130% Un – Minimum:...
See full description See full description

Description

Description

  • Measurement range: Un=400/230VAC.
  • Contacts (N)-L1-L2-L3.
  • Measurement functions: phase sequence & phase loss, undervoltage (UNDER), undervoltage & phase sequence control (UNDER+SEQ), min-max control (WIN), min-max control & phase sequence (WIN+SEQ).
  • Settings: delay – max – min – function.
  • Tripping delay: 0.1s – 10s.
  • Cut-off limit: Maximum 80% to 130% Un – Minimum: 70% to 120% Un.
  • Supply voltage: 3(N)-400/230VAC -30% to +30%.
  • Output: one changeover contact 1C/O, 5A/250VAC.
  • Operating indications with LED (SEQ, MAX, MIN, R).
  • Width: 17.5mm.
  • Can be used in a single-phase network by bridging the terminals of the 3 phases.


Manufacturer

See full description

Specifications

Specifications

Type
Three-phase
Digital
No

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

  • Measurement range: Un=400/230VAC.
  • Contacts (N)-L1-L2-L3.
  • Measurement functions: phase sequence & phase loss, undervoltage (UNDER), undervoltage & phase sequence control (UNDER+SEQ), min-max control (WIN), min-max control & phase sequence (WIN+SEQ).
  • Settings: delay – max – min – function.
  • Tripping delay: 0.1s – 10s.
  • Cut-off limit: Maximum 80% to 130% Un – Minimum: 70% to 120% Un.
  • Supply voltage: 3(N)-400/230VAC -30% to +30%.
  • Output: one changeover contact 1C/O, 5A/250VAC.
  • Operating indications with LED (SEQ, MAX, MIN, R).
  • Width: 17.5mm.
  • Can be used in a single-phase network by bridging the terminals of the 3 phases.